Engineering-Stream - Software for Engineering Applications
Home
Online Calculators
Downloads
Shop
About
Sizing Pulsation Dampener for Reciprocating Pumps (SI Units)
Average pressure at the pulsation dampener location, Pave
kPag
Allowable pressure fluctuations as % of mean pressure, delta
%
Polytropic exponent of charge gas, N (For Nitrogen, N = 1.4)
Pump Plunger Stroke Length, Ls
mm
Diameter of pump plunger, D
mm
Pump Type, PT
Select Pump Type
simplex single-acting
simplex double-acting
duplex single-acting
duplex double-acting
triplex single-acting
triplex double-acting
quadruplex single-acting
quadruplex double-acting
quintuplex single-acting
quintuplex double-acting
Pump factor, K
Minimum Acceptable Valley Pressure, Pmin
kPag
Maximum Acceptable Peak Pressure, Pmax
kPag
Pulsation Dampener Volume, Vpd
mm3
Pulsation Dampener Volume, Vpd_m3
m3
Submit
Help
General Notes:
Note: Refer to the "Terms and Conditions" in the 'About' section before using the software.
1) Pump Pulsation Dampener Sizing Program is a software program that can be used to calculate the size of pulsation dampeners for reciprocating pumps.
2) The procedure is based on GPSA Engineering Data Book - 14th Edition.
3) If you notice any error, please let us know, so that can be rectified.
4) Contact us with any comments / questions : engineeringstream11@gmail.com
5) Visit us for more software programs at https://engineering-stream.com